Herunterladen Inhalt Inhalt Diese Seite drucken

Lenze 931M Kommunikationshandbuch Seite 80

Servo drives 930 fluxxtorque
Inhaltsverzeichnis

Werbung

10
Anhang
GSD-Datei
MaxTsdr_9.6 = 60; max. response time at 9.6kB
MaxTsdr_19.2 = 60; max. response time at 19.2kB
MaxTsdr_93.75 = 60; max. response time at 93.75kB
MaxTsdr_187.5 = 60; max. response time at 187.5kB
MaxTsdr_500 = 150; max. response time at 500kB
MaxTsdr_1.5M = 300; max. response time at 1,5MB
Redundancy = 0; no redundancy
Repeater_Ctrl_Sig = 0; not connected
24V_Pins = 0; not connected
Freeze_Mode_supp = 1; supported
Sync_Mode_supp = 1; supported
Auto_Baud_supp=0; supported
Set_Slave_Add_supp = 0; not supported
Min_Slave_Intervall = 50; max. every 5ms a new DP data exchange telegram
Modular_Station = 1; modular device;
Max_Module = 1
Max_Input_Len = 20
Max_Output_Len = 12
Max_Data_Len = 32
Module="PPO Typ3" 0xf1
EndModule
Module="PPO-Write Typ3, PPO-Read Typ4" 0xf1,0xd3
EndModule
Module="PPO Typ1" 0xf3,0xf1
EndModule
Module="PPO-Write Typ1, PPO-Read Typ2" 0xf3,0xf1,0xd3
EndModule
Max_Diag_Data_Len = 9
Unit_Diag_Bit(0) = "ZK-Spg < 180V"
Unit_Diag_Bit(1) = "B-Spg < 20V"
Unit_Diag_Bit(2) = "Motortemperatur > 140°C"
Unit_Diag_Bit(3) = "Elektroniktemperatur > 78°C"
Unit_Diag_Bit(4) = "ZK-Spg > 400V"
Unit_Diag_Bit(5) = "Störung Schnellstop"
Unit_Diag_Bit(6) = "Störung bei Referenzfahrt"
80
K-HB 13.0001-DE 2.1

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

931w

Inhaltsverzeichnis