Electronic controller for ventilated refrigeration units.
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 34
PARAMETER H60 CONFIGURATION (default vector values)
Parameter DESCRIPTION
Setpoint. Control value whose range is between the minimum Setpoint LSE and the maximum Setpoint HSE.
SEt
The SEtpoint is visible from the machine status menu and not from the programming menu.
diFferential. Compressor relay activation differential; the compressor stops on reaching the Setpoint value (as
diF
indicated by the regulation probe) and restarts at a temperature value equal to the Setpoint plus the value of the
differential. N.B.: diF cannot be equal to 0.
Higher SEt. Maximum value that can be assigned to the Setpoint.
HSE
N.B.: The two Setpoints are interdependent: HSE cannot be less than LSE and vice-versa.
Lower SEt. Minimum value that can be assigned to the Setpoint.
LSE
N.B.: The two Setpoints are interdependent: HSE cannot be less than LSE and vice-versa.
defrost type. Type of defrost.
0 = electric defrost - compressor OFF during defrost cycle.
dty
1 = cycle inversion defrost (hot gas) - compressor ON during defrost cycle.
2= "Free": defrost independent of compressor
defrost interval time. Interval between the start of two consecutive defrost cycles.
dit
0 = function disabled (defrost NEVER performed).
defrost Counting type. Selects the count mode for the defrost interval.
0 = compressor running hours (DIGIFROST® method); Defrost active ONLY when the compressor is on.
N.B.: compressor running hours are counted separately from the evaporator probe (count active
also when evaporator probe missing or faulty).
dCt
1 = appliance running hours; defrost counting is always active when the machine is on and starts at each
power-on.
2 = compressor stop. Every time the compressor stops, a defrost cycle is performed according to parameter dtY;
3 = not USED
dOH
defrost Offset Hour. Defroststart delay time after request.
dEt
defrost Endurance time. Defrost time-out; determines the maximum defrost duration.
dSt
defrost Stop temperature. Defrost end temperature (determined by the evaporator probe).
defrost (at) Power On. Determines whether the instrument must enter defrost mode (if the temperature
measured by the evaporator allows this operation). n = no, does not start defrosting at start-up; y = yest, starts
dPO
defrost at start-up.
Fan Stop temperature. Fan block temperature; if the evaporator probe reads a higher value than the set value,
FSt
the fans are stopped. The value is either positive or negative and, depending on parameter FPt, can be either
the absolute temperature or the temperature relative to the Setpoint.
Fdt
Fan delay time. Fan activation delay after a defrost cycle.
dt
drainage time. Dripping time.
defrost Fan disable. Allows exclusion of the evaporator fans to be selected or not selected during defrosting.
dFd
y = yes; n = no.
Fan Compressor OFF. Selects or deselects fan deactivation at compressor OFF.
n = fans off.
FCO
y = fans on (with thermostat; depending on the value read by Pb2, see parameter "FSt").
dc = duty cycle (via parameters "Fon" and "FoF").
Fan delay Compressor off. Fans switch-off delay after compressor stop; in minutes.
FdC
0= function excluded.
Power-on Alarm Override. Alarm override time after device is switched on following a power failure.
PAO
This parameter refers to high/low temperature alarms only.
defrost display Lock. Display mode during defrost.
0 = displays the temperature read by probe Pb1.
1 = locks the reading at the temperature value read by thermostat probe when defrosting starts and until the
ddL
next time the set point value is reached.
2 = displays the label "deF" during defrosting and until the next time the Setpoint value is reached (or until
Ldd has elapsed).
H42
Evaporator probe (Pb2) present. n= not present; y= present.
IWP750 + IWK HORIZ PLUS DISPLAY
VALUE OF PARAMETER H60
RANGE
UM
1
2
5.0 ... 15.0
°C/°F
15.0
0.0 -22.0 0.0 -22.0 0.0
0.1 ... 30.0
°C/°F
2.0
2.0
5.0 ... 302
°C/°F
15.0
5.0 -18.0 5.0 -18.0 0.0
-58.0 ... 15.0
°C/°F
5.0
-5.0 -25.0 -5.0 -25.0 0.0
0/1/2
num
2
1
0 ... 250
hours
3
3
0/1/2/3
num
0
0
0 ... 59
min
0
0
1 ... 250
min
20
20
-50.0 ... 150
°C/°F
150 20.0 20.0 30.0 30.0
n/y
flag
n
n
-50.0 ... 150
°C/°F
40.0 40.0 40.0 40.0 40.0
0 ... 250
min
0
3
0 ... 250
min
0
2
n/y
flag
n
y
n/y/dc
num
y
y
0 ... 99
min
0
0
0 ... 10
hours
4
4
0/1/2
num
0
0
n/y
flag
n
y
3
4
5
6
2.0
2.0
2.0
0.1
1
0
0
0
3
3
3
0
0
0
0
0
0
0
0
0
20
30
30
1
0.0
n
n
n
n
0.0
3
3
3
0
2
2
2
0
y
y
y
n
y
y
y
n
0
0
0
0
4
4
4
0
0
0
0
0
y
y
y
n
10/11

Quicklinks ausblenden:

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Iwk

Inhaltsverzeichnis