9. Troubleshooting

Problems
Load connected to generating set when starting.
Air filter (fig. A - mark 13) clogged.
Fuel tap (fig. A – mark 5) turned off.
Fuel level too low
Engine won't
Fuel filter (fig. A – mark 12) clogged.
start
Oil level too low.
Faulty starter battery (fig. A - mark 14).
Fuel supply blocked or leaking
Fuel level too low
Engine stops
Oil level too low.
Circuit breakers (fig. A – marked 7) not interlocked.
Faulty appliance supply lead.
No
electrical current
Faulty electrical sockets (fig. A - mark 9).
Faulty alternator.
Interlocking of
Appliance connected or faulty lead.
the circuit
Excessive load (see § Generating set capacity).
breakers
No
working hours
Working hours counter fuse (fig. A - mark 8) faulty.
counter

10. Specifications

Model
Maximum output / Rated output
Acoustic pressure at 1 m
Engine type
Recommended fuel and fuel tank capacity
Recommended oil and oil sump capacity
Oil failure cut-out
Circuit breaker
Direct current
Alternating current
Socket type
Spark plug type
Battery
Dimensions l x w x h
Weight (without fuel)
●: standard
Probable causes
○: option
Disconnect the load.
Clean the air filter (see § Cleaning the air filter).
Turn on the fuel tap.
Fill–up with fuel (see § Filling with fuel).
replace the fuel filter (see § Replacing the fuel filter).
Check the oil level and add oil as required. (see
§ Checking oil level).
Recharge or replace the starter battery.
Have it checked, repaired or replaced.*
Fill up with fuel (see § Filling with fuel).
Check the oil level and add oil as required (see
§ Checking oil level).
Interlock the circuit breakers.
Change the lead.
Have them checked, repaired or replaced.*
Have it checked, repaired or replaced.*
Disconnect the appliance and the lead.
Remove the excessive load.
Have it checked, repaired or replaced.
* Operation(s) to be entrusted to one of our dealers.
Diesel
SAE 15 W 40
2P+T-230V-10/16A
X: not possible
Possible solutions
DIESEL 10000 E XL C
9000 W / 7200 W
96 dB(A)
Kohler KD425-2
X
230V - 31,3A
2P+T-230V-16A
X
89,5 x 57 x 77 cm
162 kg
35 L
1,8 L
2P+T-230V-32A