Herunterladen Diese Seite drucken

Jacuzzi Young Collection series Installations Anweisung Seite 11

Vorschau ausblenden Andere Handbücher für Young Collection series:

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

VARIATION FOR MODELS WITHOUT WALL-MOUNTED GLASS
PANELS
i
I (
15A detail 1) Position compensator "E" on the wall, ac-
cording to the given measurements.
Check that it is level and mark the holes for drilling holes as shown.
WARNING! Measurements refer to the edge of the shower tray, not
the wall.
i
I (
15A detail 2) Remove the compensator, drill the holes and
insert the dowels. Apply silicone to the rear part of the compen-
sator as shown (detail 3). Then replace the compensator and, af-
ter checking that it is level, fasten it as shown (detail 4).
Installing glass panel "F"
i
I (
18 detail 1) Fasten the foam rubber protective strip to the
part of the glass panel that faces the wall.
i
I (
18 detail 2) Then insert glass panel "F" into the fixture panel
as shown and slide it until the required distance is obtained, check-
ing that it is perpendicular with the fixture panel (details 3-4).
Installing compensator "G"
i
I (
19 detail 1) Drill holes in compensator "G", using the holes
shown as a guide.
i
I (
19 detail 2-3) Line compensator "G" up with the profile as
shown and mark the holes for drilling.
i
I (
19 detail 4) Remove the compensator, drill holes and in-
sert the dowels. Then replace the compensator and fasten it as
shown (detail 5).
i
I (
20 detail 1) Check that the glass panel and the column are
perpendicular. Then, using as a reference the holes compensator
"G", after checking for level, drill the profile of glass panel "F"; then
attach the compensator with the screws indicated.
The maximum projection allowed for the glass panel in relation to
the compensator is 10 mm.
i
I (
20 detail 2) Using the appropriate tool, insert seal "L2" be-
tween the glass panel and the fixture panel, making sure it is in the
correct position.
VARIATION FOR MODELS WITHOUT WALL-MOUNTED GLASS
PANELS
i
I (
19A detail 1-2) Position compensator "G" on the wall, ac-
cording to the given measurements.
Check that it is level and mark the holes for drilling holes as shown.
WARNING! Measurements refer to the fixture panel wall.
i
I (
19A detail 3) Remove the compensator, drill the holes and
insert the dowels. Apply silicone to the rear part of the compen-
sator as shown (detail 4). Then replace the compensator and, af-
ter checking that it is level, fasten it as shown (detail 5).
INSTALLING THE EXTERNAL GLASS PANELS
Installing glass panel "H"
i
I (
21-21A) Apply silicon on the inner part of the compensator
as shown and insert the crystal "H" in the compensator "G (det.1-
2).
WARNING! For the version with wall mounted glass panels, check
that the edges of the profiles of the two glass panels match perfect-
ly.
Installing glass panel "I"
i
I (
22-22A-22B-22C) Apply silicone on the inner part of the
compensator as shown and insert the glass panel "I" in the com-
pensator "E".
WARNING! For the version with wall mounted glass panels, check
that the edges of the profiles of the two glass panels match perfect-
ly.
Installation of the hydraulic crosspiece
i
I (
23 detail 1) Screw the glass panel support (A) into the hy-
draulic beam (B).
Screw the rainfall shower head into the hydraulic beam and se-
cure all by tightening the headless screws (det.2).
Fasten the beam to the column with the nut and O-ring provided
(det.3).
ATTENTION! for the 70 Sphere version, make sure the washers "R"
are installed in the correct direction (det.4).
I (detail 4) Fasten the glass panels using the components provid-
ed with the glass panels, following the indicated supply diagram.
I (detail 5) If the glass panels are not level, turn the adjustment
ring nuts.
I (detail 6) Once the glass panel is perpendicular, fasten the cross-
piece.
I (detail 7) Make the plumbing connection shown in the figure,
placing the gasket.
Installing door "P"
i
I (
24 detail 1) Attach the handles to the door as shown. Then
insert the bushes into the hinges (detail 2).
i
I (
25 detail 1) Insert the plastic spacers under the door. Then
line it up with glass panel "H", inserting the door hinges into the
ones on the fixed glass panel, and fasten them with the threaded
pins (detail 2).
i
I (
26) Check for perfect closing of the magnets, as well as the
distance (which must be constant) between the lower edge of the
door and the tray (with the plastic spacer). If this does not occur,
turn the adjustment ring nuts (detail 1) or, on the magnetic gas-
kets, use a wood block and a rubber mallet (detail 2).
When adjustment is complete, tighten the screws and screw in the
coverings (det. 3).
11

Werbung

loading