Herunterladen Inhalt Inhalt Diese Seite drucken

HBM TB1A Montageanleitung Seite 33

Vorschau ausblenden Andere Handbücher für TB1A:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Nominal (rated) torque M
for reference only
Supplementary reliability data
Mechanical shock, degree of
precision to DIN IEC 68; part
2‐27; IEC 68‐2‐27‐1987
Number
Duration
Acceleration (half‐sine)
Vibration stress test, degree of
precision to DIN IEC 68, part
2‐6: IEC 68‐2‐6‐1982
Frequency range
Duration
Acceleration (amplitude)
Protection class according to
EN 60 529
Weight, approx. (without cable)
1)
Each type of irregular stress (bending moment, lateral or longitudinal force, exceeding nominal
(rated) torque) can only be permitted up to its specified static loading limit provided none of the
others can occur at the same time. If this condition is not met, the limit values must be reduced. If
30% of the bending moment limit and lateral force limit occur at the same time, only 40% of the
longitudinal force limit is permissible and nominal (rated) torque must not be exceeded. The
permissible bending moments, longitudinal forces and lateral forces can affect the measurement
result by approx. 1% of nominal (rated) torque.
2)
The nominal (rated) torque must not be exceeded.
TB1A
NVm
100
N
ft-lb
75
n
ms
2
m/s
Hz
h
2
m/s
kg
0.9
A0162-8.0 HBM: public
200
500
1k
150
375
750
1000
3
650
5...65
1.5
50
IP 54
1.8
3.5
3.5
Specifications
2k
5k
10k
1,500
3,750
7,500
5.8
14
15.2
31