Attaching the grinding disc

CAUTION!
Disconnect the compressed air tool from
the compressed air supply before replacing
the accessory tool or accessories, or before
carrying out adjustments or servicing. The
spindle
must be at a standstill.
Lock the spindle
Place the rear clamping flange
. This is correctly attached if the spindle
cannot be rotated.
Place the open-ended spanner
over the collar of the rear clamping flange
prevent it from turning.
Attaching the grinding disc
Place the grinding disc
flange
.
The grinding disc
the rear clamping flange
Fixing/loosening the front flange
The 2 sides of the front flange
Screw the front flange
follows:
For thin grinding discs (see figure 1):
The collar on the front flange
so that the thin grinding disc
clamped.
fig. 1
GB │ CY
10 
on the spindle
supplied
on the rear clamping
must be evenly placed on
.
are different.
onto the spindle
as
faces upwards
can be safely
≤ 3,2 mm
For thick grinding discs (see figure 2):
fig. 2
The collar on the front flange
so that the front flange
to the spindle
Locking the spindle
Tighten the front flange
to
tion using the two-hole spanner
Loosening the front flange:
Lock the spindle
Undo the front flange
direction using the two-hole spanner

Fitting the connector nipple

Remove the plastic protective cap from the
appliance's air inlet.
Wrap the threads on the connector nipple
with the teflon tape
Screw the connector nipple
12
faces downwards
can be safely attached
.
.
in a clockwise direc-
.
.
in an anticlockwise
supplied.
into the air inlet.
PDWS 125 A1