Before beginning installation procedures,
these installation and operating instruc-
tions should be studied carefully. The in-
stallation and operation should also be in
accordance with local regulations and ac-
cepted codes of good practice.

1. General description

The GRUNDFOS MAGNA UPE Series 2000 is a
complete range of circulator pumps with integrated
differential pressure control enabling adjustment of
pump performance to the actual system require-
ments. In many systems, this will mean a considera-
ble reduction in power consumption, prevent noise
from thermostatic valves and similar fittings, and im-
prove the control of the system.
The desired head can be set on the pump control
panel.
4
The following functions can be set by means of the
pump control panel, see fig. 20, page 16:
Page
• AUTO (factory setting).
4
During operation, the pump can automatically re-
5
duce the factory-set setpoint and adjust it to the
5
actual system characteristic. This setting ensures
5
minimum energy consumption and will be the opti-
mum setting in most installations.
5
5
• Proportional-pressure control.
5
The head is changed continuously in accordance
6
with the flow demand in the system. The desired
6
setpoint can be set on the pump control panel.
6
• Constant-pressure control.
6
A constant head is maintained, irrespective of flow
7
demand. The desired setpoint can be set on the
pump control panel.
8
8
• Automatic night-time duty.
The pump changes automatically between normal
8
duty and night-time duty on the basis of the flow-
8
pipe temperature. The control modes mentioned
9
above and constant-curve duty can be combined
9
with automatic night-time duty.
10
10
The R100 remote control, the connection to an exter-
10
nal fault signal transmitter or the application of the
11
digital input offer further functions:
11
• Constant-curve duty.
11
The pump runs at a constant speed on or between
11
the max. and min. curves (to be selected with the
14
R100).
15
• Temperature influence.
15
The head varies depending on the liquid tempera-
15
ture (to be selected with the R100).
16
• External start/stop.
17
The pump can be started or stopped via the digital
18
input.
19
• External fault signal.
19
The pump controls an external fault signal trans-
20
mitter via a potential-free output.
21
Additional functions can be obtained by fitting an
22
expansion module to the pump:
23
GENI module:
24
• External analog control of head or speed from
24
an external 0-10 V signal transmitter.
• External forced control via inputs for:
- Max. curve,
- Min. curve.
• Bus communication via GENIbus.
The pump can be controlled and monitored by a
GRUNDFOS Pump Management System 2000, a
building management system or another type of
external control system.
• Control of twin-head pumps.
The control of twin-head pumps is described in
sections 1.1 and 6.11.4.
LON module:
• Bus communication via LON.
This module enables connection to a network
based on LonWorks
units which are based on this communication
standard.