3. OPERATING ELEMENTS

Fuel valve
The fuel valve opens and closes the fuel line between fuel tank and
carburettor.
This lever must be set to ON to start the engine.
The fuel valve must be set to OFF if the engine is not operated to
prevent "flooding" of the carburettor and possible gasoline spilling.
FUEL
VALVE
OFF
Throttle lever
Use the throttle lever (mounted on the machine) to adjust the
rotational SPEED.
Moving the throttle lever in the direction indicated increases
or reduces
the engine speed.
FAST
Ignition switch
The engine switch (mounted on the machine) turns the ignition
system on or off.
The switch must be set to ON ( I ) to start the engine.
17
OPERATING ELEMENTS / CHECKS BEFORE STARTING
ON
OFF
SLOW
OFF
IGNITION SWITCH
ON
The engine stops when the switch is moved to OFF ( O ).
Choke lever
The choke lever opens and closes the choke valve in the
carburettor.
In the CLOSED position the fuel mixture is enriched for cold
starting.
In the OPEN position the correct fuel mixture is supplied for the
operation following the engine start and for restarting a warm
engine.
...OPEN
CLOSED
Cranking rope handle
Pulling the cranking rope handle starts the engine.
CRANKING

4. CHECKS BEFORE STARTING

IS THE ENGINE READY TO START?
To ensure your safety and to maximize the service life of the engine its
condition must be checked before each start. Correct any possible
problems or have them remedied by your customer service before
starting the engine.
Improper maintenance or troubleshooting prior to starting may trigger
malfunctions and cause serious injuries.
Regular inspections before starting help prevent problems.
CHOKE LEVER