Herunterladen Inhalt Inhalt Diese Seite drucken

Torques; Mechanical Installation - Grundfos SRG.10.30.606 Montage- Und Betriebsanleitung

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 41
12
18
19
2
1
23
1
Fig. 2
Open installation
Pos.
Designation
Bottom fixation bracket and guide
1
claws on connection flange*
2
Column profile
5
Top fixation bracket
12
Crane foot
13
Crane with winch and lifting wire
15
Lifting wire incl. wire clamp
17
Cable clamp
Cable sock, incl. shackle ∅10
18
19
Intermediate fixation bracket
23
Connection flange
*
Guide claws are only available for SRG.xx.80.
8

4.2 Torques

All nuts and screws used for the installation must be
made of stainless steel.
13
Use grease (Alu-paste) together with a spring
washer or lock nut; otherwise, use Loctite or a
similar product for lubrication and locking.
5
All stainless-steel nuts and screws must be tightened
to the following torques:
Screws F-Class 70
15
M6
17
M8
M10
M12
M16
M20

4.3 Mechanical installation

See section
1. Weld the connection flange to the cast-in pipe
end in the tank.
2. Weld the profile section to the connection flange
and pipe end. Place it in position 12 o'clock.
Fig. 3
3. SRG.xx.80.xx: Weld the guide claws to the
connection flange. See fig. 4.
Fig. 4
Screws F-Class 80
[Nm]
8.8
21.4
44
74
183
370
4.2 Torques
and fig. 2.
Profile section on connection flange
Position of guide claws
[Nm]
11.8
28.7
58
100
245
494

Werbung

Inhaltsverzeichnis
loading