Herunterladen Inhalt Inhalt Diese Seite drucken

Symbols Used; Installation Instructions; Intended Use; Approval - Truma Combi D 6 Einbauanweisung

Vorschau ausblenden Andere Handbücher für Combi D 6:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 3
Combi D 6
Table of contents
Symbols used ...................................................................... 13
Installation instructions .................................................. 13
Intended use ........................................................................ 13
Approval .............................................................................. 13
Regulations .......................................................................... 13
Installation instructions for vehicles .................................... 13
Choice of location ............................................................ 14
Fastening the appliance .................................................. 14
Exhaust and combustion air ducting ............................ 15
Permissible duct lengths ..................................................... 15
Assembly of wall cowl ........................................................ 15
Extraction air supply ........................................................... 16
Recirculated air intake .................................................... 16
Warm air distribution ...................................................... 17
Fuel connection ................................................................ 17
Safety instructions for routing fuel lines ............................. 17
Installing the metering pump .............................................. 17
Fuel tank removal kit ....................................................... 18
Water connection ............................................................. 18
Installing FrostControl (safety/drain valve) .......................... 19
Routing of water pipes ........................................................ 19
Installing the room temperature sensor ...................... 20
Installing the control panel ............................................ 20
Accessories for the control panel ................................. 20
Electrical connections ..................................................... 20
Connection 12 V ............................................................... 21
Connecting control panel to the unit .................................. 21
Connecting metering pump ................................................ 21
Extraction fan connection ................................................... 21
Initial start-up ................................................................... 21
Filling the fuel lines ............................................................. 21
Function check ................................................................ 21
Warning information ....................................................... 21

Symbols used

Symbol indicates a possible hazard.
Comment including information and tips.
Observe the ESD-regulations! An electro-static charge
can destroy the electronics. Ensure potential equalisa-
tion before touching the electronics.

Installation instructions

The installation and repair of the appliance is only to be
carried out by an expert. Read the installation instructions
carefully prior to starting work and observe the instructions!
Non-compliance with installation instructions or
incorrect installation can result in endangerment
of persons and property.
Please pay attention to the ESD regulations!

Intended use

The Combi D diesel heater is a warm-air heater with integrated
hot water boiler (10 litre volume). This unit was designed for
installation in motor homes and caravans.
An additional altitude kit (part no. 34610-01) is required for long
periods of heater operation at altitudes of 1500 to 2750 m.

Approval

The heater is approved for installation in passenger vehicles
(class M1 motor homes) with no more than 8 seats excluding
the driver's seat, and for trailers (class O caravans).
Installation inside busses and vehicles (vehicle classes M2 and
M3) is not permitted.
The applicable regulations must be complied with when the
equipment is being installed in special vehicles and vehicles
for transporting hazardous goods.
Other forms of use are also possible after consultation with
Truma.
The year when the equipment was first taken into oper-
ation must be indicated with a check on the type plate.

Regulations

Guarantee claims, warranty claims and acceptance of liability
will be ruled out in the event of the following:
-
modifications to the unit (including accessories),
-
modifications to the exhaust duct and the cowl,
-
failure to use original Truma parts as replacement parts and
accessories,
-
failure to follow the installation and operating instructions.
It also becomes illegal to use the appliance, and in some
countries this even makes it illegal to use the vehicle.

Installation instructions for vehicles

Installation in vehicles must be in line with the regulations of
the respective country in which it is used. The national legisla-
tion and regulations must be observed.
The relevant employer's liability insurance association accident
prevention regulations must be observed in Germany for vehi-
cles used for commercial purposes.
In other countries, the relevant regulations must be observed.
More information on the regulations in the relevant destina-
tion countries can be requested from our foreign representa-
tives (see Truma Service Booklet or www.truma.com).