Herunterladen Inhalt Inhalt Diese Seite drucken

Cleaning Of The Spray Gun - SATA SATAjet 1000 B Betriebsanleitung

Vorschau ausblenden Andere Handbücher für SATAjet 1000 B:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 5
Operating Instructions SATAjet 1000 B RP/HVLP
7.4. Painting
Fully pull trigger for painting [6-1]. Operate spray gun according to [6-2].
Maintain spray distance as described in chapter 2.
8.

Cleaning of the Spray Gun

• Prior to cleaning, please disconnect the paint spray gun from the com-
pressed air circuit!
• Risk of injury due to unexpected leakage of compressed air or mate-
rial!
• Empty paint spray gun and gravity flow cup completely, dispose of
paint material appropriately!
• Disassemble and install components very carefully! Exclusively use
included special tools!
• Use neutral cleaning solution (pH value 6 to 8)!*
• Do not use acids, lyes, pickling agents, unsuitable re-
claimed materials or other aggresive cleaning media, such
as Toluol, for example!*
• Do not soak paint spray gun in cleaning solution!*
• Drillings are to be cleaned with SATA cleaning brushes or SATA nozzle
cleaning needles only. The use of other tools may cause damage or
may affect the spray pattern. Recommended accessory: cleaning kit
Art. No. 64030.
• Exclusively use spray gun washing machines recommended by SATA!
Please observe the operating instructions!
• The air passages have to put under pressure with clean compressed air
during the entire cleaning process!
• Nozzle head has to point downwards!
• Remove the spray gun from the gun washing machine right
after the cleaning process!*
• Never use ultrasonic cleaning devices - leads to damage of noz-
zle set and gun surface!
• After cleaning, the spray gun, the material passages, the air cap
including thread as well as the gravity flow cup have to be blown
dry with clean compressed air!*
Warning! Attention!
EN