• Protect the electric plug con-
nections against moisture.
• If there is a risk of flooding,
fix the plug connections in an
area that is safe from flood-
ing.
• Ensure that the mains voltage
matches the specifications on
the rating plate.
• Connection to the mains
must be carried out by an
experienced electrician and
meet the requirements of
IEC 60364-1.
• The electrical installation
shall be according to nation-
al wiring rules.
• The device must only be con-
nected to a mains socket
via a residual-current circuit
breaker (RCD) with a rated
leakage current of not more
than 30 mA. Fuse: at least
13 ampere.
• Before each use, check the
equipment, cable and plug
for damage.
• If the power cable for this
equipment is damaged, it
must be replaced by the
manufacturer, a customer ser-
vice agent of the same or a
similarly qualified person in
order to prevent hazards.
• Do not pull the plug from the
socket by the cable. Protect
the cable from heat, oil and
sharp edges.
• Do not carry or fix the equip-
ment by the cable.
• Use only extension cables
that are protected from spray
water and designed for out-
door use. Always fully unroll
a cable drum before use.
Check the cable for damage.
• Before any work on the
equipment, during work
breaks and in the case of
non-use, remove the plug
from the socket.
• The cross-section of the pow-
er supply cable must not be
less than 2 x 2,5 mm².
• Wear sturdy footwear to pro-
tect against electric shock.
• To protect against electric
shock, operate the equipment
only in an upright position.

Start-up

In keeping with current regulations a
pressure cleaner must never be oper-
ated off the drinking water mains
supply without a controllable back-
flow preventer. A suitable backflow
preventer in conformity with
EN 12729 type BA must be used.
Water that has passed through a backflow
preventer is classified as undrinkable.
A backflow preventer is available in spe-
cialist shops.
A system separator (check valve) prevents
the backflow of water and detergent into
the drinking water pipeline.
Employ an ordinary garden hose for
the water intake and ensure sufficient
length.
Use the device on a domestic water
connection with an output of at least
450 l/h.
Irrespective of the water pipe, you can
also use the device (for example, rain
barrel) through the integrated water
suction function. This function must only
be used with a suction hose with a fil-
ter basket.