The motor switches on until the re-
quired pressure has built up. After
the pressure has built up, the motor
switches off.
3. Press the gun (16) starting lever (21).
The nozzle operates by pressure and
the motor switches back on.
Releasing the starting lever (21) causes
the equipment to switch off. The system
remains pressurised.
The turbo dirt blaster (24) produces a
rotating water jet and is designed for
low water consumption work.
The standard Vario nozzle (18) pro-
duces a flat wide jet particularly suited
for large surfaces.
Turn the tip of the nozzle left to reduce
the width of the jet. Turn the tip of the
nozzle right to expand the width of
the jet.
The rotating washing brush (2) is ba-
sically used without pressure exertion.
The cleaning function results from the
rotary movement and the water flow.
The wash brush does not rotate if the
water flow is missing.
In the event of leaks in the
water system, switch off the
equipment immediately at
the on/off switch (7) and dis-
connect the equipment from
the mains at the mains pow-
er cord. Risk of electric shock!
Start afresh with making the
water connections (cf. "Start-
up / Operation" from point
2.).
If there is still air in the device,
please proceed as follows:
To vent the supply hose:
1. Remove the quick connector for gar-
den hose adapter (25) on the water
connection coupling (13) and turn the
water tap on until the water comes out
without bubbles.
2. Switch off the water tap.
3. Connect the supply hose to the water
connection (14) on the equipment us-
ing the quick connector for garden
hose adapter (25).
4. Fully open the water tap.
To vent the equipment:
5. Switch on the on/off switch (7) until
pressure has built up.
6. Switch off the on/off switch (7).
7. Press the on lever on the gun (16) until
the pressure has gone.
8.
Please repeat process 5. to 7. a few
times until there is no more air in the
device.
• You can lock or unlock the start
B
lever (21) of the spray gun (16)
by pressing the locking button
(22).
Lock the starting lever (21) to
prevent the pressure cleaner
from being inadvertently / ac-
cidentally started.

Interrupting operation

Release the lever of the gun (16).
During prolonged work intervals turn
off the pressure cleaner by its ON /
OFF switch (7).
If the equipment falls over,
switch off the equipment
immediately at the on/off
switch (7) and disconnect the
equipment from the mains at
the mains power cord.
of electric shock!
should the equipment be re-
turned to an upright position.
For your own safety, wait
approx. 5 minutes before re-
connecting to the electricity.