Herunterladen Inhalt Inhalt Diese Seite drucken

Start-Up; Setting Up - Parkside PHD 170 B2 Originalbetriebsanleitung

Vorschau ausblenden Andere Handbücher für PHD 170 B2:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 60
GB
MT
• The device must only be con-
nected to a mains socket via
a RCD (Residual Current De-
vice) with a rated leakage cur-
rent of not more than 30 mA.
Fuse: at least 13 ampere.
• Before each use, check the
equipment, cable and plug
for damage.
• If the power cable for this
equipment is damaged, it
must be replaced by the
manufacturer, a customer ser-
vice agent of the same or a
similarly qualified person in
order to prevent hazards.
• Do not pull the plug from the
socket by the cable. Protect
the cable from heat, oil and
sharp edges.
• Do not carry or fix the equip-
ment by the cable.
• Unsuitable extension cables
can be dangerous. If an ex-
tension cable is used it must
be suitable for outdoor use,
and be routed above the
ground. We recommend us-
ing a cable drum that holds
the socket at least 60 mm
above the ground.
Check the cable for damage.
• Before any work on the
equipment, during work
breaks and in the case of
non-use, remove the plug
from the socket.
• The cross-section of the pow-
er supply cable must not be
less than 2 x 2,5 mm².
• Wear sturdy footwear to pro-
tect against electric shock.
• To protect against electric
shock, operate the equipment
only in an upright position.
52
• Always shut off the power
switch when leaving the ma-
chine unattended.

Start-up

In keeping with current regulations a
pressure cleaner must never be oper-
ated off the drinking water mains
supply without a controllable back-
flow preventer. A suitable backflow
preventer in conformity with
EN 12729 type BA must be used.
Water that has passed through a backflow
preventer is classified as undrinkable.
A backflow preventer is available in spe-
cialist shops.
A system separator (check valve) prevents
the backflow of water and detergent into
the drinking water pipeline.
Use a commercially available 1/2"
garden hose, at least 5 m long, for wa-
ter supply.
Do not exceed a length of 30 m.
Use the device on a domestic water
connection with an output of at least
450 l/h.

Setting up

1. Pull the curved handle (2) up as far as
it will go.
2. Connect the high-pressure fitting (jet
gun) (29) to the jet gun (14). Ensure
that the hose runs to the front, so as not
to impede the handle (2).
3. Connect the feed hose to the water
supply and allow water to escape from
the other end of the feed hose with no
bubbles, in order to expel the air from
the feed hose. Switch off the water tap.
4. Connect the feed hose with the help of
the quick connector for garden hose
adapter (22) with the water connection

Quicklinks ausblenden:

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Ian 346400 2004

Inhaltsverzeichnis