Residual Risks; Initial Start-Up; Securing The Disc Sanding Device; Mounting / Dismounting The Sanding Table - Parkside PTSG 140 B2 Originalbetriebsanleitung

Vorschau ausblenden Andere Handbücher für PTSG 140 B2:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 4
G B
I E
the damaged cable and pull the
mains plug if the cable is da-
maged while working. Damaged
cables increase the risk of electric shock.
• Avoid abnormal body postures.
Ensure secure footing and keep your
balance at all times.
• To avoid hazards, any replacement of
the plug or the connection line must
always be executed by the manufactu-
rer of the electric tool or their customer
service.
• Water must be kept away from the po-
wer tool's electrical parts and people
within the working range.
• Caution! Never remove any loo-
se splinters, chips or jammed pi-
eces of wood when the sanding
disc is still running. Always switch
off the machine before repairing any
faults or removing jammed pieces of
wood - pull the mains plug.

Residual risks

Even if properly operating and handling this
electric tool, some residual risks will remain.
Due to its construction and build, this electric
tool may present the following hazards:
a) Lung damage, if suitable respiratory
protection is not worn.
b) Hearing damage, if suitable ear pro-
tection is not worn.
c) Damages to health due to
- touching the area of the grinding tool
which was not covered;
- the ejection of pieces from workpiece
or damaged grinding discs.
d) Damage to your health caused by
swinging your hands and arms when
operating the appliance for longer pe-
riods of time or if the unit is not held or
maintained properly.
2 2
Warning! During operation, this
electric tool generates an electro-
circumstances, may impair the
functionality of active or passive
medical implants. To reduce the risk
of serious or lethal injuries, we rec-
ommend that persons with medical
implants consult their doctor and the
manufacturer of their medical im-
plant before operating the machine.

Initial start-up

Avoid unintentional starting.
Ensure that the mains plug is remo-
ved before carrying out any adjust-
ments, maintenance or repair work.
Before operating the disc sanding device,
you must secure it against tipping.
A
B
C
Securing the disc
sanding device
K
L
M
Secure the disc sanding device horizon-
tally (
) or vertically (
surface.
U
V
W
The enclosed screw clamp (16) must grip
into one of the two receptors (4).
Mounting / dismounting
the sanding table
Dismounting the sanding table:
1. Release the screw (9) underneath the
sanding table (11) using the hexagon
socket wrench enclosed (17).
2. Remove the screw (9) and the washer
(8) and pull the sanding table holder
(10) away from the device.
D
E
F
N
O
P
) to the working
X
Y
Z
G
H
Q
R