Ex relevant specifications

Change from one to two columns
4
Ex relevant specifications
4.1

Basic requirements

Follow the operating instructions to ensure proper installation. The relevant operating
instructions for the meter contain all installation and safety instructions. The icon on the name
plate indicates the following:
Depending on the application, operators must comply with relevant national installation
specifications (e.g., NEC, CEC, ATEX137, IEC60079-14, etc.).
Important
For explosion-proof devices/devices with flameproof enclosures, remove the locking device
before opening the housing cover and reattach it after closing the housing!
The max. ambient temperature for use with combustible dusts (category II 2D) is always
T
After switching off the power supply, wait t > 2 minutes before opening the converter
housing. Observe the "DELAY BEFORE OPENING > 2 MINUTES" warning message on
the housing cover.
When commissioning the flowmeter, refer to EN50281-1-2 regarding use in areas with
combustible dusts.
For Ex devices in PTFE design, the minimum conductivity of the medium must be > 10
S/m.
When selecting the medium, take into consideration the chemical resistance of the
materials for the meter housing, the liner and the gaskets for the process connection.
If zone 0 is present in the metering tube, the meters may only be installed in an area close
by to ensure sufficient ventilation of zone 1.
Variable area flowmeters used in accordance with maximum electrical values for a
category 3 device (zone 2) can also be used without modification as category 2 devices in
an explosion-proof/flameproof enclosed zone 1 (see section "5.3.1 Later change of Ex
protection classes" in the operating instruction).
Use only a damp cloth to clean the window in order to avoid electrostatic charging.
For information about installation conditions for thermal insulation, see chapter "Operating
conditions", page 12 .
Use slow opening valves.
Comply with installation conditions as per VDI/VDE 3513.
Avoid gas inclusions when using the meter with fluids.
Avoid pulsating flow. A float damper is available as an option.
Avoid gas impurities (see Federal Institute for Geosciences and Natural Resources (BGR)
132-7.3.2.2.2).
16 - EN
To ensure proper operation, comply with the supplementary safety
information in the operating instructions and certificates.
= +60 °C.
amb
VA Master FAM540
-8
CI/FAM540-X1