Commissioning

Earthing connection (PE)
For protection against interference, the screens of the signal lines and the
power line must be connected on both sides. Potential differences cause
inadmissible currents on the screen. Install the PE connection
protective earth conductor potential between the plug connectors (see
Fig.
in the scope of delivery). For multiple position indicators we recommend
connecting the earthing to a ground bar
Fig. 7: Ground bar
Admissible power input
Supply for the position indicator shall be sized sufficiently. Current draw is
NOTICE
temporarily higher than nominal current at the moment of switching on.
For the supply value refer to the technical data in chapter 9.
5 Commissioning
Display and control keys
The position indicator has a two-line display with special characters and
three control keys. The position indicator is configured and controlled via
the keys. The LEDs
(factory setting), the 1st line displays the actual value and the 2nd line
the set point. With a critical battery status, the special sign
with an empty battery,
surement switched on, the incremental measurement symbol
displayed.
AP05 · Date 25.09.2018 · Art. No. 88847 · Mod. status 316/18
6). Use 6.3 mm flat connectors with short strands 2.5 ... 4 mm² (not
serves for positioning monitoring. In the basic state
1
(see
Fig.
1
1
glows permanently. With incremental mea-
English
onto the
3
7).
blinks,
is
29