Installation
WARNING
NOTICE
NOTICE

4.3 Electrical installation

Destruction of parts of equipment and loss of regulation control
` Use of screened connection cable with trunk cable in pairs. Pairs to be
allocated differential-signal wise (D+, D-), (T+, T-), (A, /A), (B, /B)
(Recommendation: encoder/-resolver line from Messrs. LAPP-Kabel,
5*2*0,14²+2*0,5², type-no.: 70388728).
` Current linkage: don't connected or removed live.
` Perform wiring work in the de-energized state only.
` Use strands with suitable ferrules.
` Prior to switching on check all mains and plug connections.
` Switch on operating voltage together with downstream electronics (e.
g., control unit).
Basically, all connections are protected against external interference.
Choose a place of operation that excludes inductive or capacitive interfer-
ence influences on the actuator. When mounting the system keep a maxi-
mum possible distance from lines loaded with interference. If necessary,
provide additional installations including screening shields or metallized
housings.
` Pay attention to the maximum length of the connection cable between
sensor and downstream electronics.
` Do not use tinned strands in connection with screw clamp connec-
tions.
SSI pin assignment
• plug pin 12 pin M12 A coded

viewing side = plug-in side


Pin
Signal with LD Signal without LD Description
1
nc
2
D+
3
D-
4
T-
5
+UB
MSAC501 · Date 30.04.2018 · Art. No. 88113 · Mod. status 167/18
nc
nc
D+
SSI data + or DÜA in service
mode
D-
SSI data - or DÜB in service
mode
T-
SSI cycle input -
+UB
power supply sensor