Herunterladen Inhalt Inhalt Diese Seite drucken

Temperature; Temperature Upper-Limit; Temperature Lower-Limit - Hirschmann Hios-3S Rsp Referenzhandbuch

Inhaltsverzeichnis
Verfügbare Sprachen

Verfügbare Sprachen

System

90.2 temperature

Configure the upper and lower temperature limits of the device. The device
allows you to set the threshold as an integer from -99 through 99. You confi-
gure the temperatures in degrees Celsius.

90.2.1 temperature upper-limit

Configure the upper temperature limit.
Mode: Global Config Mode
Privilege Level: Administrator
Format: temperature upper-limit <P-1>
Parameter Value
-99..99
P-1

90.2.2 temperature lower-limit

Configure the lower temperature limit.
Mode: Global Config Mode
Privilege Level: Administrator
Format: temperature lower-limit <P-1>
Parameter Value
-99..99
P-1
RM CLI HiOS-3S RSP
Release 6.1 09/2016
Meaning
Upper temperature threshold ([C], default
70).
Meaning
Lower temperature threshold ([C], default
0).