Technical data

Mechanical data
Housing
Sensor/band reading dis-
tance
Cable sheath
Electrical data
Operating voltage
Current consumption
Power input
SSI clock speed input
Output circuit
Cycle time
Mounting
(Fig.
9)
1. Mount seal
to screen ring
3
2. Slip parts
...
1
3. Strip cable sheath, isolate conductor.
4. Shorten and turn down screen.
5. Clamp strands into socket
4.4).
6. Mount parts
...
2
7. Screw pressure screw
Fig. 9: Straight mating connector M12
10 Technical data
aluminium
0.1 ... 1 mm
PVC
10 ... 30 V DC
<125 mA
<3 VA
<500 kHz
SSI, RS485
<650 μs