• Remove the cover from the station
• Check the seal on the tank
• Clean the tank, motor and float with a high-pressure cleaner
• Fill the tank until the pump starts
• Once the pump starts, part of the water is drained
• After the pump stops, switch off the system
• Close the supply valves and the shut-off valve (not supplied on SANIFOS
• Drain the rest of the water in the tank by means of a water suction device or other pumping method
• With the valve closed, unscrew the fitting (bottom of tank on SANIFOS
• Remove the pump from the tank (using the cable on SANIFOS
• Check the general condition of the pump, electrical cables, float (switching on, tripping) and the blade. Contact SFA Technical Service if a
replacement element is faulty.
• Clean and check for the correct functioning of the non-return valve.
• Lower the pump back into the tank
• Screw the fitting back onto the pipe
• Open the valves
• Power on again
• Perform several switching on/switching off tests using the water points
• Close the cover and tighten the bolts after greasing them (on SANIFOS
138
110)
®
110) which connects the pipework to the pump body
®
250 and SANIFOS
500)
®
®
250 and SANIFOS
500)
®
®