3. DESCRIPTION

3.1 General description

SANIFOS
110, SANIFOS
250 and SANIFOS
®
®
small-scale use (small buildings, shops, public places).
They are not intended for rainwater pumping.
They can be installed, placed inside the house or buried outside.
The tanks of the stations are made from high density polyethylene and have a high mechanical resistance, are odour-
resistant, UV-resistant and resistant to chemical attack. Their lid is held in place by stainless steel screws (except the
SANIFOS
110).
®
The tanks of the stations are delivered with 1 or 2 pumps depending on the model. These pumps are available with an SFA maceration
system that allows the discharge of wastewater in DN 40 (outer diameter 50) or with a vortex system for the discharge of wastewater
in DN 50 (outer diameter 63).
These tanks have several inlets of different diameters for the inlet of the effluents (refer to the dimensions on page 11).
These devices comply with the EN 12050-1 standard (pumping station for waste water containing faeces) as well as the European
directives on construction products, electrical safety and electromagnetic compatibility.
DoP available on our website in the product file ("Diagrams and technical data sheet" tab).
They must be installed in accordance with standards EN 12056-4 for indoor installation and EN 752 for outdoor installation.

3.2 Scope of supply

SANIFOS
110
®
On a pallet:
• SANIFOS tank
110 litres with cover and gasket
®
• Pre-assembled hydraulics in the tank
• SANIPUMP
submersible pump with float switch (float cable H07RN-F 2 x 1 mm² + earth), mounting base and H07RN-F-3G type 1.5
®
mm² pump supply cable of 10 meters in length (in a separate package)
• In an accessory bag: 1 cable gland
Note : the shut-off valves and the non-return valve are not supplied with the SANIFOS
SANIFOS
250
®
On a pallet:
• SANIFOS
tank 250 litres with cover, screw and gasket
®
• Hydraulic pre-assembled in the tank including 1 shut-off valve and 1 non-return valve
• SANIPUMP
submersible pump with float switch (float cable H07RN-F 2 x 1 mm² + earth), mounting base and H07RN-F-3G type 1.5
®
mm² pump supply cable of 10 meters in length (in a separate package)
• In an accessory bag: 1 handling cable + 1 terminal block IP68 + 1 cable gland, cable clips, screws
SANIFOS
500
®
On a pallet:
• SANIFOS
500 litre tank with cover, screw and gasket
®
• Hydraulic pre-assembled in the tank including 2 shut-off valves, 2 non-return valves and 3
floats directly installed in the tank (float cable 07RN-F 2 x 1 mm²)
• 2 submersible SANIPUMP
®
• SMART remote control box with power cable type H07RN-F-3G1.5 mm² (2.5 m length),
power cables for pumps type H07RN-F-4G1.5 mm² (4 meters long), float connection cables
(4 meters) and quick connectors. For the three-phase version, power cables type H07RN-
F-5G 2.5 mm² (2.5 m long), power cables for pumps type H07RN-F-4G1.5 mm² (4 meters
in length).
• HF remote alarm unit
• Accessory bag with: 2 handling cables, 5 cable glands (2 x PG13 and 3 x PG11), 2 x IP 68
waterproof terminal blocks: 4 conductors for pumps, 3 terminal blocks IP 68: 2 conductors
for floats, cable clips, screws.
A 30 cm height extension is available for the SANIFOS
11 and 12).

3.3 Rating plate

1
9
118
500 are wastewater pumping stations specially developed for private, commercial and
®
pumps with mounting base (in 2 separate packs)
250 and SANIFOS
®
3
2
8
7
®
500 (see pages
®
1 Name of the pumping station
2 Power consumption of the engines
4
5
3 Supply voltage
4 Frequency
5 Protection index
6 Date of production
7 Identification number
8 Declaration of performance reference (DoP)
6
9 Type of certification
110.