Tighten the screws in the bracket and on the wall (figure 14, pos. D). Lock the brackets into position using the locking
screws (figure 14, pos. E).

6.3.2.3 Optional installation in a cupboard with a base

1.
Using a saw, cut out a hole in the base of the cupboard. When the SAVE VTR 150/B unit is mounted directly on the
wall, the minimum distance from the wall to the hole has to be 55 mm (figure 15, pos. A).
Note:
Be sure to add the thickness (dimension X) of your wooden blocks if they were used (figure 15, pos. B).
2.
Attach the brackets as far into the cooker hood as possible. Insert the cooker hood up into the hole in the base of the
cupboard. Pull out (figure 16, pos. A) and use screws to fasten the brackets to the sides of the cupboard (figure 16,
pos. B). Tighten the brackets in the cooker hood.
6.3.3

Unit mounting and cooker hood wiring

Mounting the unit with attached cooker hood
1. Pull the cooker hood power supply and control cables to the top since the mounted SAVE VTR 150/B unit will block
access to the back.
212024 | A001
Fig. 15 Dimensions of a hole in the base of the cupboard
Fig. 16 Installation using brackets