• Depending on the cupboard depth and selected kitchen furniture panel installation method, the SAVE VTR 150/B unit
may have to me shifted forward using wood blocks at the back.
• Solutions how to hang this panel are described further in this document, see 6.4 Installation of a kitchen furniture
panel, page 23.
Make sure to find a correct depth for installation of the SAVE VTR 150/B unit before proceeding with the mounting
bracket installation on the wall.
The SAVE VTR 150/B is supplied with approximately 1,9 m of power cable and fitted with a plug for 230 V~, single
phase earthed connection located at the top of the unit.
Recommended installation location for the outdoor air intake is the northern or eastern side of the building and with a
distance to openings for discharge of stale ventilation air, kitchen ventilator, central vacuum system, waste water drain-
age and other pollution sources like exhaust from traffic etc. Stale discharge air should ideally be led via a roof unit to
the outside and with a good distance to any outdoor air intake, windows etc.
6.2.1

Wall preparation for mounting bracket

Important
Make sure to read all instructions before proceeding with installation procedure. Installation steps can vary
depending on the type of installation.
1. Prepare the surface where the unit is to be mounted. Make sure that the surface is flat, vertical and that it supports
the weight of the unit. Perform the installation in accordance with local rules and regulations.
If the wall is from a thick concrete or bricks, no special preparation is needed (figure 5, pos. A), otherwise make nec-
essary adjustments (figure 5, pos. B). The unit weights 46 kg.
Make sure there is a power socket is located nearby the unit, preferably above it. It must be earthed. SAVE VTR 150/
B power cable length is 1,9 m and it comes out from the top left side in right version units and from the right top side
in left version units. Choose power socket location accordingly.
212024 | A001
Fig. 5 Surface preparation.
C — concrete/bricks, W — wood block, G — gypsum, M — mineral wool