Herunterladen Inhalt Inhalt Diese Seite drucken

Location And Space Requirements; Wall Preparation For Mounting Bracket; Outdoor Air Intake Location Recommendation; Access To Power Supply - SystemAir SAVE VSR 150/B Installationsanleitung

Vorschau ausblenden Andere Handbücher für SAVE VSR 150/B:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

10
| Prerequisites for Installation
B. Horizontal wall installation Left and right connections are possible.
A wall mounting kit is required. Not delivered with the unit.
C. Vertical wall installation with the supply air
A wall mounting kit is required. Not delivered with the unit.
D. Vertical wall installation position D with the supply air
heat from the re-heater is rising in the unit.
E. Upside down installation is NOT allowed.
F. Installation on the floor is not allowed.
6.1

Location and Space Requirements

The SAVE VSR 150/B should preferably be installed in a separate room (e.g. storeroom, laundry room or similar.).
Note:
SAVE VSR 150/B must be installed in a heated
area.
When choosing the location it should be kept in mind that
the unit requires maintenance regularly and that the in-
spection door should be easily accessible. Leave free
space for opening the door and for taking out the main
components.
6.2

Wall preparation for mounting bracket

The unit should be installed in such a way that there is no vibration noise coming from the wall on which the unit is
installed.
6.3

Outdoor Air Intake Location Recommendation

Recommended installation location for the outdoor air intake is the northern or eastern side of the building and with a
distance to openings for discharge of stale ventilation air, kitchen ventilator, central vacuum system, waste water drain-
age and other pollution sources like exhaust from traffic, etc. Exhaust air should ideally be led via a roof cowl to the out-
side and with a good distance from the outdoor air intake, windows, etc.
6.4

Access to Power supply

The SAVE VSR 150/B is supplied with approximately 1,5 m cable and plug for 230V, single phase earthed connection.
Make sure a power outlet is reachable by the plug.
upwards is allowed.
downwards is not allowed due to the fact that the
GB
212964 | v3.1

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis