Herunterladen Inhalt Inhalt Diese Seite drucken

Declaration Of Conformity - Endress+Hauser procom DZL 363 Ex-Dokumentation Zu Den Betriebsanleitungen

Vorschau ausblenden Andere Handbücher für procom DZL 363:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Procom DZL 363 with Promass 63

Declaration of conformity

Type
Certificate of Conformity
through Endress+Hauser Flowtec AG acc.
to Directive 94/9/EC (ATEX) and IEC 79-15
resp. prEN 50021
(special conditions see page 6)
Certificate of Conformity
through Endress+Hauser Flowtec AG acc.
to Directive 94/9/EC (ATEX) and IEC 79-15
resp. prEN 50021
(special conditions see page 6)
Transmitter Procom DZL 363
(non-intrinsically safe signal current circuit connection to Promass 63)
Procom DZL 363-1.****
Procom DZL 363:
Measuring system Promass 63
(compact version, non-intrinsically safe signal current circuit connection to Procom DZL 363)
Promass 63****-*******1**.
Promass 63 A/F
Promass 63 I/M
Electronics housing Promass 63
(remote version, non-intrinsically safe signal current circuit connection to Procom DZL 363)
Promass 63****-*******1**.
Promass 63
Sensor Promass (remote version)
Promass 63 A DN 1...4
Promass 63 F DN 8...50
Promass 63 F DN 80...100
Promass 63 I DN 8...40
Promass 63 I DN 50 bzw. DN 40 "FB" f II3G EEx nLR IIB T3-T6 X (prEN) resp. Ex nR IIB T3-T6 X (IEC)
Promass 63 M DN 8...50
Promass 63 M DN 80
Endress+Hauser
Description
for the measuring system Promass 63
Labelling:
f II3G EEx nRVW IIC/IIB T6-T2 X (prEN)
Ex nACR IIC/IIB T6-T2 X (IEC)
for the electrical device Procom DZL 363
Labelling:
f II3G EEx nVW IIC T4 (prEN)
Ex nAC IIC T4 (IEC)
0 → Dx signal current circuit, data only, two-wire connection
(this corresponds to code L with Promass 63)
5 → DoS signal current circuit, two-wire connection,
data incl. power supply for Promass 63
(this corresponds to code G with Promass 63)
f II3G EEx nVW IIC T4 (prEN) or Ex nAC IIC T4 (IEC)
G → DoS signal current circuit
(this corresponds to code 5 with Procom DZL 363)
L → Dx signal current circuit
(this corresponds to Code 0 with Procom DZL 363)
f II3G EEx nRVW IIC T2-T6 X (prEN) resp. Ex nACR IIC T2-T6 X (IEC)
or
f II3G EEx nRVW IIB T2-T6 X (prEN) resp. Ex nACR IIB T2-T6 X (IEC)
f II3G EEx nRVW IIC T3-T6 X (prEN) resp. Ex nACR IIC T3-T6 X (IEC)
or
f II3G EEx nRVW IIB T3-T6 X (prEN) resp. Ex nACR IIB T3-T6 X (IEC)
G → DoS signal current circuit EEx e connection
(this corresponds to code 5 with Procom DZL 363)
L → Dx signal current circuit EEx e connection
(this corresponds to code 0 with Procom DZL 363)
f II3G EEx nVW [L] IIC/IIB T5-T6 X (prEN) or Ex nAC IIC/IIB T5-T6 X (IEC)
f II3G EEx nLR IIC T2-T6 X (prEN) resp. Ex nR IIC T2-T6 X (IEC)
f II3G EEx nLR IIC T2-T6 X (prEN) resp. Ex nR IIC T2-T6 X (IEC)
f II3G EEx nLR IIB T2-T6 X (prEN) resp. Ex nR IIB T2-T6 X (IEC)
f II3G EEx nLR IIC T3-T6 X (prEN) resp. Ex nR IIC T3-T6 X (IEC)
f II3G EEx nLR IIC T3-T6 X (prEN) resp. Ex nR IIC T3-T6 X (IEC)
f II3G EEx nLR IIB T3-T6 X (prEN) resp. Ex nR IIB T3-T6 X (IEC)
en
Fig. 1
Transmitter Procom DZL 363
Fig. 2
Compact version
Promass 63 measuring system
Fig. 3
Remote version
Promass 63 electronics housing
and sensor
5

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis