en
Note!
4
Temperature tables of Promass 63
Compact version
at Ta = 40 °C
Promass 63 A (DN 1...4)
Promass 63 F (DN 8...100)
Promass 63 I (DN 8...50)
Promass 63 M (DN 8...80)
at Ta = 60 °C
Promass 63 A (DN 1...4)
Promass 63 F (DN 8...100)
Promass 63 I (DN 8...50)
Promass 63 M (DN 8...80)
For the 63A/F sensors, the minimum fluid temperature is –200 °C, and for the 63 I/M
sensors the minimum fluid temperature is –50 °C.
Remote version (sensor)
at Ta = 60 °C
Promass 63 A (DN 1...4)
Promass 63 F (DN 8...100)
Promass 63 I (DN 8...50)
Promass 63 M (DN 8...80)
For the 63A/F sensors, the minimum fluid temperature is –200 °C, and for the 63 I/M
sensors the minimum fluid temperature is –50 °C.
Remote version (electronics housing)
• PROMASS 63* ***-*******1*** has the T6 temperature class up to an ambient
temperature of Ta = 40 °C.
• PROMASS 63* ***-*******1*** has the T5 temperature class up to an ambient
temperature of Ta = 60 °C.
Note!
At the fluid temperatures given, and for a certain temperature class, the components
will not be subjected to any non-permissible temperatures.
Explanation of Promass I
DN 16 = DN 15 "FB"
DN 26 = DN 25 "FB"
DN 41 = DN 40 "FB"
"FB" = Full bore
Procom DZL 363 with Promass 63
Max. fluid temperature [°C] in
T6
T5
T4
80
95
130
80
95
130
80
95
130
80
95
130
Max. fluid temperature [°C] in
T6
T5
T4
–
95
130
–
95
130
–
95
130
–
95
130
Max. fluid temperature [°C] in
T6
T5
T4
80
95
130
80
95
130
80
95
130
80
95
130
T3
T2
190
200
190
200
150
–
150
–
T3
T2
190
200
190
200
150
–
150
–
T3
T2
190
200
190
200
150
–
150
–