If the sauna control unit is used without a humidity temperature sensor
(FTS2), cyclic mode is activated. If the sauna room temperature is less
than 30 °C, the vaporizer is activated continuously for a preset time
(10 minutes by default). Normal cyclic mode then starts.
EN 60335-2-53:2011; characteristic temperature / relative humidity for proper use.

10.5. Post-drying program

Once combi-mode has finished, the post-drying program starts automati-
cally to prevent mould or rot from forming in the sauna room. This involves
heating the sauna room to 80 °C with the fan running for 30 minutes.
► To cancel the post-drying program, press rotary selector 1 while
simultaneously turning it to the right.
To prevent mould and rot from forming, the post-drying program should
NOT be cancelled.
Temperature °C
p. 39/64
EN