Installation instructions, only for experts

5.7. Safety shut-off

EN 60335-2-53 states that sauna control units with a remote start or preset timer
function may only be used for operating and regulating a sauna heater which
has satisfied the combustion test described in paragraph 19.101. Alternatively,
a suitable safety shut-off device can be installed in or above the heater. This shuts
the sauna heater off if items such as a towel are placed on the sauna heater.
To install the safety shut-off device, perform the following steps:
1. Install the safety shut-off device in accordance with the operating instructions
for the device.
2. Feed the wires for the safety shut-off device through the cable gland 2 into
the low-voltage connection area.
3. Connect the wires for the temperature sensor to the terminals labelled "OSG"
in terminal strip c.
If a safety shut-off is not installed, a jumper must be fitted at the terminals
labelled "OSG".

5.8. Additional output

The additional output can, for example, be used for an infra-red lamp or infra-red
heater panels.
1. Feed the connection cable for the additional device through the cable gland 9
into the connection area for 230 V/400 V.
2. Connect the power supply cables to terminal strip g in accordance with the
terminal diagram. Observe the operating instructions and safety instructions
for the appliance concerned.
Please note the maximum connected load of the additional output:
● Dimmable up to a maximum of 500 W
● Switchable up to a maximum of 3500 W

5.9. Foil sensor (optional)

1. Feed the wires for the sensor through the cable gland 8 into the low-voltage
connection area on the expansion module.
2. Connect the sensor cables for the sensor to the terminals labelled "FOIL
SENSOR" in terminal strip f.