• This device was designed to be permanently
secured and connected on a building or on a
suitable structure. The device must be permanently
secured and connected before any operation.
• Comply with all the national standards during the
device installation.
• Installation category (also called Overvoltage
Category) specifies the level of mains voltage
surges that the equipment will be subjected to.
The category depends upon the location of the
equipment, and on any external surge protection
provided. Equipment in an industrial environment,
directly connected to major feeders/short branch
circuits, is subjected to Installation Category III. If
this is the case, a reduction to Installation Category
II is required. This can be achieved by use of an
insulating transformer with an earthed screen
between primary and secondary, or by fitting UL
listed Surge Protective Devices (SPDs) from live
to neutral and from neutral to earth. Listed SPDs
shall be designed for repeated limiting of transient
voltage surges, suitable rated for operating voltage
and designated as follows: Type 2 (Permanently
connected SPDs intended for installation on the
load side of the service equipment overcurrent
device); Nominal Discharge Current (In) 20kA min.
For example: FERRAZ SHAWMUT, STT2240SPG-
CN, STT2BL240SPG-CN rated 120Vac/240Vac,
(In=20kA). Maximum distance between installation
and reduction is 5m.
• Any device which could be installed inside the
product must comply with the current safety
standards.
• If the installation is NEMA TYPE 4X, the installer
must replace the cable glands of the product with
NEMA TYPE 4X cable glands.
• Power supply to the product must be exclusively
provided by the PoE cable (Power over Ethernet).
• For all connections, use cables that are able to
withstand temperatures of at least 75°C (167°F).
• The product is designed to house only cameras
that are properly certified (7W max).
4
• A power disconnect device must be included in
the electrical system, and it must be very quickly
recognizable and operated if needed.
• To connect the power supply line use the
appropriate junction-box (UPTJBUL). For further
information, refer to the product use and
installation manual.
• Use Listed copper tube crimping lugs for the
connection of the network conductors to the
terminals. The copper tube crimping lugs must
be suitable for the type of installation (from -20°C
(-4°F) a +80°C (+176°F) min., V-0). Copper tube
crimping lugs examples: RP, BP o YP (Cembre).
4 Identification
4.1 Product description and type
designation
The HOV Hi-PoE IPM housing optimally exploits POE
and Hi-POE technology, using the power supplied
by the Ethernet cable as the sole source of power
for all connected devices, thus ensuring maximum
efficiency and flexibility of the network system as well
as user-friendly installation and low costs.
The innovative IPM (Intelligent Power Management)
system enables extremely quick and easy installation
with the use of a single Ethernet connecting cable.
The Hi-POE IPM system automatically detects all
the options, like heating, fan and illuminator and
then autonomously balances the power to ensure
suitable distribution of the same to the connected
devices. This guarantees the optimal operation of the
IP camera between -30°C (-22°F) and +60°C (140°F),
with heat regulation and cold start (activation at low
temperature).
The Analogue system, with previously installed
camera housings, can be retrofitted on IPM system
simply by changing the slide and the internal
electronics. This enables the digital conversion,
speeding up the installation and thereby minimizing
costs and environmental impact.