HOV HI-POE IPM AVAILABLE MODELS AND FEATURES
Operating
Injector
temperature
From -10°
PoE class 3
(14°F) up to
(13W)
+60°C (140°F)
Hi-PoE class 4
(25W)
From -10°
PoE class 3
(14°F) up to
(13W)
+60°C (140°F)
Hi-PoE class 4
(25W)
From -30°C
Hi-PoE class 4
(-22°F ) up to
(25W)
+60°C (140°F)
Hi-PoE class 4
(25W)
Tab. 3

8 Switching on

The automatic pre-heating (De-Ice) process
could be started whenever the device is
switched on and the air temperature is
below 0°C. This process is used to ensure
that the device works properly even at
low temperatures. The duration ranges
depending on environmental conditions
(from 60 minutes up to 120 minutes).
During the lighting phase the device reads the
status of the dip switch and automatically detects
all the connected options for the correct energy
management of the housing.
10
Camera
Demisting
system
PoE max. class
p
2 (7W)
PoE max. class
p
3 (13W)
PoE max. class
p
2 (7W)
PoE max. class
p
3 (13W)
PoE max. class
p
3 (13W)
PoE max. class
p
3 (13W)
Illuminator
Heater
p
p
p
p
The LEDs shown in the figure allow to check the
product's operating status.
Fig. 14
Refer to the table to identify the operating status.
Anti-icing
Fan with dou-
heated glass
ble air filter
p
p
p
MNVCHOVHPOE_1642_EN