Herunterladen Inhalt Inhalt Diese Seite drucken

Intrinsic Error And Operating Error - Bosch FSA 050 Betriebsanleitung

Hybridtester
Vorschau ausblenden Andere Handbücher für FSA 050:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 4
Dimensions
�unction
�pecification
Tester
220 x 92 x 50 mm (8.66 x 3.63 x 1.97 inch)
Tester + case
456 x 178 x 89 mm (18 x 7 x 3.5 inch)
Weight
�unction
�pecification
FSA 050
800 g
FSA 050 + case
1.75 kg
�use
R
Only use 500 mA (FF), 1000 V, 32 x 6 mm ceramic
fuse with a high blow capacity of at least HBC 50 kA.
Use is not to be made of glass fuses.
�afety class
R
The FSA 050 meets the requirements of EN 61010-1
(2001) for 600 V phase to ground, category IV.
R
The connection terminals supplied meet the require-
ments of EN 61010-1 (2001) and have the measuring
category 600 V CAT III / 1 kV CAT II.
Application
R
BS EN 61010 defines the measurement categories I
to IV with reference to transient overvoltages and the
location within electrical installations. The FSA 050
is intended for use in category IV (primary supply
level) for systems with 600 V phase to ground.
Temperature coefficient
R
<0.1 % per °C up to 1 GΩ
R
<0.1 % per °C per GΩ above 1 GΩ
Ambient conditions
�unction
Operating range
Operating humidity
Storage temperature range
Calibration temperature
Maximum usage altitude
Protection against dust
and water
Robert Bosch GmbH
�pecification
-20 to +55 °C
95 % rel. 0 °C to +35 °C,
70 % RH +35 °C to +55 °C
-30 to +80 °C
+20 °C
2000 m
IP54
Technical data | ��A ��� | ��
8.
Intrinsic error and opera-
ting error
The intrinsic error is the maximum inaccuracy of the
FSA 050 under ideal conditions, whereas the operating
error is the maximum inaccuracy with allowance for
battery voltage, temperature, interference, system vol-
tage and system frequency.
Intrinsic error
Refer to Section 8 -Technical data.
Operating error
�unction
�pecification
Insulation range
±15 % ± 2 positions
Continuity range
±26 % ± 2 positions
Resistance range
±12 % ± 2 positions
Voltage range
±10 % ± 2 positions
Capacitance range
±18 % ± 2 positions
Frequency range
±5 % ± 2 positions
en
|
1 689 989 102
2011-04-26