– If there is a gas system leak, close the cylinder valve, have the gas
system repaired by an expert immediately and do not open the
valve any more in the meantime.
– Unscrew the pump from the test connection and screw the screw
cap back onto the test connection.
– Press the yellow reset button (7), turn it slightly clockwise, hold it
for 5 seconds and ensure that it remains in the "ready for opera-
tion" position (see Figure 2a).
– It is essential to reattach the screw cap (10) every time after it has
been removed.

Maintenance

The MonoControl CS gas pressure regulator is maintenance-free.
In Germany, the gas system must be retested every 2 years by a lique-
fied gas specialist (DVFG, TÜV, DEKRA). The test must be confirmed
on the respective test certificate (G 607).
In countries where testing is not mandatory, we recommend that the
gas system be tested every 2 years for your own safety.
The filter pad in the gas filter must be replaced every time the gas cyl-
inder is replaced (see gas filter operating instructions).