Problem
You cannot fix the
locking arm in the
upper closed posi-
tion.
When turning the
selection dial to the
desired speed, the
display is illumina-
ted, but the motor
does not start.
Liquids run down
on the exterior of
the glass jug and/
or accumulate under
the motor base duri-
ng operation.
Reason
Only when using
the juicing system,
you must (and can)
engage the locking
arm.
The junction bet-
ween glass jug and
blade assembly is
not turned on suffici-
ently tight.
The thread between
blade assembly and
glass container is
tilted.
The processing sys-
tem is not locked to
the motor base suffi-
ciently tight.
The glass jug is
overfilled.
Some liquid has
been spilled while
filling the glass jug.
You did not close
the glass jug with
the appropriate lid
or the lid has not
been closed proper-
ly, during operation.
The Solution
With any optional accessory simply leave the locking arm in
the horizontal position. The appliance will recognize the type of
system installed.
Switch "OFF" the appliance and unplug from the power supply.
Remove the processing system from the motor base. Try to turn
on the blade assembly a little more tightly. Due to the sealing
ring, there is a firm resistance when screwing on the blade
assembly.
Switch "OFF" the appliance and unplug from the power supply.
Remove the processing system from the motor base. Unscrew
the blade assembly. Then re-assemble the processing system
without tilting the threads to avoid damage and ensure correct
and leak-free operation (See: 'Assembling the Glass Jugs').
Switch "OFF" the appliance completely. Clasp the collar of the
blade assembly with both hands and turn the blade assem-
bly clockwise a little more. When feeling the first resistance,
you must turn the blade assembly a little more than a finger's
breadth to lock the processing system onto the motor base
(see: 'Processing Your Food').
Immediately unplug the appliance. Then clean the appliance
(see: 'Care and Cleaning'). Leave the motor base dry naturally
for 1 day.
Always observe the maximum filling level for each glass contai-
ner (see: 'Technical Specifications').
Immediately unplug the appliance. Then clean the appliance
(see: 'Care and Cleaning'). Leave the motor base dry naturally
for 1 day. Whenever possible, you should remove the glass jug
from the motor base for filling. Otherwise, carefully avoid spil-
ling liquids onto the exterior of the appliance. Always wipe spil-
led liquids off immediately.
Immediately unplug the appliance. Then clean the appliance
(see: 'Care and Cleaning'). Leave the motor base dry naturally
for 1 day. Always ensure to close the lid correctly, before star-
ting operation.