Herunterladen Inhalt Inhalt Diese Seite drucken

Changing/ Replacing Filter; Troubleshooting - Kärcher IVS 100/55 Originalbetriebsanleitung

Vorschau ausblenden Andere Handbücher für IVS 100/55:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1

Changing/ replacing filter

1 Lid of filter chamber
2 Filter spreader
3 Washer ring
4 Filter
 Switch off the appliance and disconnect
from the network.
 Remove the hose clamp on the connec-
tion hose. Use a screwdriver.
 Open locks.
 Remove the lid of the filter chamber.
 Take out the filter.
 Check sealing ring for damage.
 Insert the new filter in reverse sequence
and take care to ensure that the filter
spreader is aligned correctly in the filter
bag.
20

Troubleshooting

Motor (suction turbine) does not start
No electrical voltage.
 Check the receptacle and the fuse of
the power supply.
 Check the power cable and the power
plug of the device.
No vacuuming operations, airflow es-
capes from the suction hose
 Suction turbine rotates in the wrong di-
rection; interchange poles at the plug.
Suction capacity decreases slowly
Filter, nozzle, suction hose or suction pipe
may be blocked.
 Check, clean the accessories, replace
the filter, if required.
Dust comes out during the vacuuming
Filter has not been fastened correctly or is
defective.
 Check to see if filter is sitting properly;
replace if required.
 Switch off the appliance, clean the filter
or insert a new filter.
Warning
Have all checks and work on electrical
parts performed by an expert. If malfunc-
tions continue, please contact the Kärcher
Customer Service.
– 8
EN

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis