Care and maintenance

Warning
First remove the mains plug before doing
any job on the vacuum cleaner.

Changing/ replacing filter

1 Lid of filter chamber
2 Filter spreader
3 Washer ring
4 Filter
 Switch off the appliance and disconnect
from the network.
 Open locks.
 Remove the lid of the filter chamber.
 Take out the filter.
 Check sealing ring for damage.
 Insert the new filter in reverse sequence
and take care to ensure that the filter
spreader is aligned correctly in the filter
bag.

Wash the filter

The filter can be washed out under running
water.
ATTENTION
Risk of damage! Do not use washing
agents or bleach. Only insert the filter into
the appliance when it is completely dry.

Troubleshooting

Motor (suction turbine) does not start
No electrical voltage.
 Check the receptacle and the fuse of
the power supply.
 Check the power cable and the power
plug of the device.
No vacuuming operations, airflow es-
capes from the suction hose
 Suction turbine rotates in the wrong di-
rection; interchange poles at the plug.
Suction capacity decreases slowly
Filter, nozzle, suction hose or suction pipe
may be blocked.
 Check, clean the accessories, replace
the filter, if required.
Dust comes out during the vacuuming
Filter has not been fastened correctly or is
defective.
 Check to see if filter is sitting properly;
replace if required.
 Switch off the appliance, clean the filter
or insert a new filter.
Warning
All checking and work on electrical parts
must be performed by an authorized elec-
trician. In the event of continuing faults,
contact Kärcher customer service.
– 7