Storage

Caution
Risk of injury and damage! Note the weight
of the appliance in case of storage.
This appliance must only be stored in inte-
rior rooms.

Maintenance and care

Warning
First remove the mains plug before doing
any job on the vacuum cleaner.
Dust extracting machines are safeguards
for the prevention or elimination of hazards
defined in the regulations of BGV A1.
In order to carry out maintenance work,
the user must disassemble, clean and
service the unit, in so far as this is pos-
sible without endangering maintenance
personnel and other persons. Suitable
precautions include decontamination
before the unit is disassembled. Pre-
cautions must be taken for local filtered
forced air ventilation at the place where
the unit is disassembled, the cleaning of
the maintenance surface and suitable
protection of the personnel.
The outside of the unit should be
cleaned thoroughly and any harmful
substances removed. Alternatively, a
sealed coating may be applied before
the unit is removed from the danger ar-
ea. All unit parts are to be considered
contaminated when they are removed
from the danger area.
In the framework of maintenance and
repair work all contaminated objects
that cannot be cleaned satisfactorily
must be disposed of. Such objects must
be disposed of in impermeable bags in
accordance with the valid provisions for
the disposal of such waste.
During the transport and maintenance
of the appliance the extraction opening
is to be closed with the connection
socket.
Warning
Safety devices which are designed to pre-
vent dangerous situations must be serviced
regularly. This means that the safety func-
tions of the devices must be subjected to a
thorough inspection, e.g. checking for
leaks and damage to the filter, and testing
the monitoring function. This must be car-
ried out by the manufacturer or a trained
person at least once a year.
No outside help is required for carrying out
basic maintenance and cleaning.
The outer surface of the device and the in-
side of the container should be cleaned
regularly using a damp cloth.
Danger
To minimise residual hazard risks during
maintenance, the following instructions
should be observed. Wear a filter mask P2
or higher and disposable clothes when car-
rying out maintenance work (e.g. filter
change).

Cleaning the filter

 Switch off the appliance using the On/
Off switch.
 Move the lever for cleaning the filter
back and forth a couple of tomes.

Changing/ replacing filter

 Switch off the appliance using the ON/
OFF switch and separate it from the
mains.
 Open the locks (A) on both the sides.
 Unlock plug (B) and disconnect.
– 7