Error Messages - Sentiotec Ck 31 Montage- Und Gebrauchsanweisung

Saunasteuerung
Vorschau ausblenden Andere Handbücher für CK 31:
Inhaltsverzeichnis
Verfügbare Sprachen

Verfügbare Sprachen

Instructions for use for the user
3. Replace fuse for the interior lighting (microfuse 5 x 20 T2.0 A/ 250 V)
or fuse for fan (sub-miniature fuse TR 5 - T 1.0 A/ 250V) 7, or fuse for the
electronics of the device (microfuse 5 x2 0 T630 mA/ 250 V) A (Fig. 3).
4. Insert tabs
2
carefully press onto the housing lower part
5. Place the housing cover
and press until it clicks audibly. Check the fit of the control unit.

9.4. Error messages

An error message indicates an electrical malfunction in the system. The sauna
control unit is no longer operational.
Error
Description
ERR 1
Excess temperature F1
defective
ERR 3
Break in sensor line F1
ERR 4
Short-circuit F1
ERR 5
Short circuit FTS2 / F2
(temperature sensor)
ERR 6
Line interruption FTS2 /
F2 (temperature sensor)
ERR 7
Line interruption FTS2
(humidity sensor) or F2
is not recognized
ERR 8
S h o r t c i r c u i t F T S 2
(humidity sensor)
WORLD OF WELLNESS
of the operating unit
onto the housing lower part
5
into the two lateral holders
1
to the stop position.
6
Cause / rectification
See point "6. Performing tests" on
page 17
See point "6. Performing tests" on
page 17
Check the sensor lines and the terminals
Check the sensor lines and the terminals
Check the sensor lines and the terminals
Check the sensor lines and the ter-
minals; restart the control unit, press
PROG/OK button for 30 seconds
Check the sensor lines and the terminals
p. 39/44