The sauna control unit is installed outside the sauna cabin or according to the
recommendation of the cabin manufacturer. The electrical supply is a fixed con-
nection. (Observe Fig. 1)
1. Gently press in lock
2. Screw in cross-head screw for the upper mounting hole
of 7 mm to the sauna wall (see detail).
3. Suspended housing lower part
head screw.

4.2. Installing the heater sensor F1 with excess temperature fuse

Note Fig. 4 (figures chapter):
● The heater sensor must be installed on the rear of the heater, above the mid-
dle of the sauna heater. An interval of approx. 15 cm to the roof of the sauna
room must be maintained.
● The heater sensor must be attached in a way that it is not affected by a flow
of air.
1. Lay the two 2-pin heater sensor wires in the wall of the sauna room, leading
them to the heater sensor installation location and affix the heater sensor
wires using wire clips.
2. Pull the two half-shells
3. Connect the four connectors for the heater sensor wire
with Fig. 4.
4. Place the connection panel
5. Place the two half-shells together, screw them together using the two Phillips-
head screws
securely closed.
6. Install the heater sensor on the rear of the heater using the two wood screws
enclosed
6
WORLD OF WELLNESS
and remove housing cover
3
of the heater sensor apart.
1
2
(9 mm) and check whether the heater sensor has been
3
(16 mm).
in position
2
1
crossways in the heater sensor half-shells.