● Post-drying programme
Once climate mode has finished, the post-drying programme starts automati-
cally to prevent mould or rot from forming in the sauna room. The post-drying
phase can last up to 85 minutes. The cabin temperature is regulated and the
fans run at different speeds.
● Excess temperature fuse
The excess temperature fuse is installed in the housing for the heater sen-
sor. Should the sauna heater continue heating after reaching the preferred
temperature due to a defect, the excess temperature fuse switches off at
a temperature of approx. 139 °C above the sauna heater.
3.4. Sauna operating modes
The CK 31 sauna control unit provides two operating modes, sauna mode and
climate mode.
Sauna mode
Dry heat is provided in sauna mode. The temperature in the room is high (80 to
100 °C) The humidity level of maximum 10% is low. The indicator lights
and
-
are red during sauna operation.
c
g
Climate mode
The evaporator operates along with the sauna heater in climate mode. The
temperature in the sauna room is lower (approx. 40 to 65 °C) than in sauna
mode, with the relative humidity being considerably higher, spanning 35% to
approximately 70%. The maximum humidity level which can be set depends
on the temperature of the sauna. The higher the sauna temperature, the lower
the maximum humidity level which can be set. The indicator lights
-
are green during climate mode.
b
g