Herunterladen Inhalt Inhalt Diese Seite drucken

Performing Tests; Connecting The Operating Unit; Finishing The Installation - Sentiotec CK 41 Montage- Und Gebrauchsanweisung

Saunasteuerung
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Installation instructions, for professionals only

5.9. Connecting the operating unit

● Guide the connection cable for the operating unit through the cable bush-
ing 9 into the low-voltage connection area 5.
● Connect the plug of the ribbon cable to the connection socket 2.

5.10. Finishing the installation

● Screw two cross-head screws into the lower fastening holes 6 (Fig. 2).
● Ensure that the sauna control unit is fitted securely.
● Place the control panel 2 onto the housing lower part 7. To do so, insert
the tabs 3 into the two lateral holders 4 and press onto the housing lower
part until the stop position (Fig. 1).
● Place the housing cover 6 onto the housing lower part 7, swivel downward
and press until it clicks audibly.

6. Performing tests

The following tests must be performed by a certified electrical fitter.
WARNING!
The following tests must be performed with the power supply
switched on. There is a danger of electric shock.
● NEVER touch live parts.
1. Check the contact of the earth conductors on the earth conductor terminal.
WORLD OF WELLNESS