4.3. Installing the heater sensor F1 with excess temperature fuse

Note Fig. 4 (figures chapter)
● The heater sensor must be installed on the rear of the heater, above the
middle of the sauna heater. A clearance of approx. 15 cm to the roof of the
sauna room must be maintained.
● The heater sensor must be attached in a way that it is not affected by a flow
of air.
1. Lay the two 2-pin heater sensor wires in the wall of the sauna room, leading
them to the heater sensor installation location and affix the heater sensor
wires using wire clips.
2. Pull the two half-shells 1 of the heater sensor apart.
3. Connect the four connectors for the heater sensor wire 5 in accordance
with Fig. 4.
4. Place the connection panel 2 crossways in the heater sensor half-shells.
5. Place the two half-shells together, screw them together using the two Phillips-
head screws 3 (9 mm) and check whether the heater sensor has been
securely closed.
6. Install the heater sensor on the rear of the heater using the two wood screws
enclosed 6 (16 mm).

4.4. Installing bench sensor F2 (optional)

Note Fig. 5 (figures chapter)
The bench sensor must be installed on the wall of the sauna room, above the
rear bench seat. A clearance of approx. 15 cm to the roof of the sauna room
must be maintained.
1. Lay the two 2-pin bench sensor wires in the wall of the sauna room, leading
them to the bench sensor installation location and affix the bench sensor
wires using wire clips.
2. Pull the two half-shells of the bench sensor apart.