1. Replace the fuse for interior lighting B (microfuse 5 x 20 T2.0 A/ 250 V) or
fuse for the electronics of the device A (microfuse 5 x2 0 T630 mA/ 250 V)
A or fuse for fan 8 (sub-miniature fuse TR5 - T1,0A/250V) (Fig. 1).
2. Insert tabs
3
carefully press onto the housing lower part
3. Place the housing cover
and press until it clicks audibly. Check the fit of the control unit.

9.4. Error messages

An error message indicates an electrical malfunction in the system. The sauna
control unit is no longer operational.
Error
ERR 1
Excess temperature F1
defective
ERR 3
Break in sensor line F1
ERR 4
Short-circuit F1
ERR 5
Short circuit FTS2 / F2
(temperature sensor)
ERR 6
Line interruption FTS2 /
F2 (temperature sensor)
ERR 7
Line interruption FTS2
(humidity sensor) or F2
is not recognized
ERR 8
Short circuit FTS2
(humidity sensor)
WORLD OF WELLNESS
of the operating unit
onto the housing lower part
6
Description
into the two lateral holders
2
to the stop position.
7
Cause / rectification
See point "6. Performing tests" on
page 18
See point "6. Performing tests" on
page 18
Check the sensor lines and the terminals
Check the sensor lines and the terminals
Check the sensor lines and the terminals
Check the sensor lines and the terminals;
restart the control unit, press PROG/OK
button for 30 seconds
Check the sensor lines and the terminals