Herunterladen Inhalt Inhalt Diese Seite drucken

Electrical Connection; Connecting The Supply Line, Heater - Sentiotec CK 41 Montage- Und Gebrauchsanweisung

Saunasteuerung
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Instructions for installation and use

5. Electrical connection

Note Fig. 2 and Fig. 6 (figures chapter)
ATTENTION!
Damage to the unit
● The sauna control unit may only be used for operating and controlling 3 heat-
ing circuits with a maximum heating capacity of 3.5 kW per heating circuit.
The maximum evaporator capacity totals 3.5 kW. Optionally with an addi-
tional power module the switching capacity can be increased from 10.5 kW
to 18 kW / 30 kW.
Observe the following points when connecting the power to the sauna control unit:
● Installation may only be performed by a qualified electrician or similarly quali-
fied person.
Please observe that in the event of a guarantee claim, a copy of the bill
from the electrician performing the work must be presented.
● Work on the sauna control unit may only be performed when the power has
been disconnected.
● There must be a fixed connection for the electrical power supply.
● An all-pole disconnecting device with full cut-off compliant with overvoltage
category III must be fitted on-site.
● Before installing the sauna control unit, take note of the requirements in the
installation and operation manual of the sauna heater manufacturer. The sauna
control unit has a connection area for extra-low voltage 5 and a connection
area for 230 V/400 V connections K (Fig. 2).
● Observe the connection diagram (Fig. 6).
● Connect all earth conductors to the earth conductor panel F (Fig. 2).

5.1. Connecting the supply line, heater

● Guide the supply and heating system lines through the installation open-
ings G, H (connection area for 230 V / 400 V I) into the housing lower part 1
and connect to the terminal L according to the circuit diagram (Fig. 6).