Instructions for installation and use
● Automatic heating period limiter
The sauna control unit shuts down automatically after the maximum heating
period for safety reasons. The maximum heating period can be set to 6 h,
12 h, 18 h or 24 h.
● Post-drying programme
Once climate mode has finished, the post-drying programme starts automati-
cally to prevent mould or rot from forming in the sauna room. The post-drying
phase can last up to 85 minutes. The cabin temperature is regulated and the
fans run at different speeds.
● Excess temperature fuse
The excess temperature fuse is installed in the housing for the heater sen-
sor. Should the sauna heater continue heating after reaching the preferred
temperature due to a defect, the excess temperature fuse switches off at
a temperature of approx. 139 °C above the sauna heater.

3.4. Sauna operating modes

The CK 41 sauna control unit provides two operating modes, sauna mode and
climate mode.
Sauna operating mode
Dry heat is provided in sauna mode. The temperature in the room is high (80 to
100 °C) The humidity level of maximum 10% is low.
Climate operating mode
The evaporator operates along with the sauna heater in climate mode. The tem-
perature in the sauna room is lower (approx. 40 to 65 °C) than in sauna mode, with
the relative humidity being considerably higher, spanning 35% to approximately
70%. The maximum humidity level which can be set depends on the temperature
of the sauna. Generally, the following applies: High temperature low humidity
and high humidity low temperature.
WORLD OF WELLNESS
p. 9/44