Installation instructions, for professionals only
Thermal safety:
● Heater sensor with excess temperature fuse. (Shutdown temperature 139 °C)
● Automatic heat duration limit after max. 6 hours (for private systems).
● Two-sensor system with temperature control over the bench.
Setting ranges:
Temperature for sauna mode:
Temperature for climate mode:
Humidity:
Fan:
Pre-set time:
Max. pre-set time:
Max. adjustable heating duration:
* EN 60335-2-53 specifies a heating time limitation of 6 h for private saunas. For sau-
nas in hotels, apartment blocks and similar locations, a maximum heating period limit
of 12 hours is permissible. Extending the heating period limit to 18 hours or 24 hours is
only permitted in public saunas.
Connected cables:
Power supply cable:
Heater supply cable (temperature-resistant up to 150 °C): min. 2.5 mm²
Sensor wires (temperature-resistant up to 150 °C):
Light wire:
Fan wire:
Maximum cable lengths:
Heater sensors F1 /F2 / FTS2: 10 m
Auxiliary power units:
S2-18:
S2-30:
WORLD OF WELLNESS
15–110 °C at bench sensor F2/FTS2
15–80 °C at bench
10–80% relative humidity
00–100% fan power
in 1 minute increments
23 hours 59 minutes
6 hours*
Increase of the switched power of 10.5 kW
to 18 kW total power;
Increase of the switched power
from 10.5 kW to 30 kW total power.
p. 44/44
min. 5 x 2.5 mm²
min. 0.5 mm²
min. 1.5 mm²
min. 1.5 mm²