11. How to Implement Sampling Setup
to show Function menu, choose "Sampling" to set sampling mode.
Click
Samping Mode
Sampling
Peak Detect
Average
Figure: Normal sampling mode display, in which no burr can be detected.
Figure: Peak Detect mode, under which the burrs on the falling edge of the square wave, can be
detected and the noise is heavy.
Figure: The displayed waveform after the noise is removed under the Average Mode, in which the
average number of 16 is set.
Description
Normal sampling mode
Use to capture maximal and minimal samples. Finding highest and
lowest points over adjacent intervals. It is used for the detection of the
jamming burr and the possibility of reducing the confusion.
It is used to reduce the random and don´t-care noises, with the editable
number (1 ≤ number ≤
-87-
128
) of averages.