In the voltage division list, you can select the proper value.
You can set the zero point position through the control bar to regulate of the vertical display position of
the signal. You can also drag the zero point position pointer (22, 23 in
7. User
Interface).
Drag the slide up to increase, down to decrease; the further from the center, the higher the changing
speed is.
Keyboard Shortcuts
Q: The voltage division of Channel 1 decreases one level
A: The voltage division of Channel 1, increases one level
W: The voltage division of Channel 2 decreases one level
S: The voltage division of Channel 2 increases one level
Cymometer
It is a 6-digit cymometer. The cymometer can measure frequencies from 2 Hz to the full bandwidth.
Only if the measured channel has triggering signal and in Edge mode, it can measure frequency
correctly. In the Single trigger mode, it is a one channel cymometer and it can only measure the
frequency of the triggering channel. In the ALT trigger mode, it is a two channel cymometer and it can
measure the frequency of two channels.