Aligning the unit and installing it
 Line up the equipment on the level area.
 Fix with the material included. Use the
inclosed spacer and set up the equip-
ment horizontal.
1 Dowel pin M10 (4x)
2 Unterlegplatte 5 mm (4x) Unterlegplatte
2 mm (4x)
3 Washer 10,5 (4x)
4 Hexagon screw M10 (4x)
Assemble the installation parts
Outside anti freeze thermostat (optional)
 Install the outside thermostat, that it is
protected from direct sun light warm
walls and air flow.
 Connect the inclosed cable in the con-
trol circuit board ( refer to pwer flow
plan).
swinging spacer (optional)
 Install the swinging spacer according to
the enclosed installation instruction on
the left side of the equipment.
Cleaning tool
 Lead the high pressure hose through
the sidewall of the equipment and con-
nect with the high-pressure pump.
 Connect the high-pressure hose with
the blowing gun.
 Connect the steel pipe brush with the
blowing gun.
 Tighten all clamping nut.
Brief instruction
 remove the brief instructionfrom the in-
struction manual, and fix it inside the
door of the circuit control board.

Water connection

Warning
Observe regulations of water supplier.
According to the applicable regula-
tions, the appliance must never be
used on the drinking water supply
without a system separator. Use a
suitable system separator manufactured by
KÄRCHER; or, as an alternative, a system
separator as per EN 12729 Type BA. Water
flowing through a system separator is con-
sidered non-drinkable.
Caution
Always connect the system separator to
the water supply, never directly to the appli-
ance!
Note
Impurities in the inlet water can damage the
unit. Kärcher recommends the use of a wa-
ter filter (see "accessories").
To ensure frost protection of the plant, the
water inlet must be protected against freez-
ing (through insulation and accompanying
heating).
Warning
Risk of damage to the plant if water supply
is not of suitable quality. Use water only of
potable quality as water supply to the plant.
Quality requirements for tap water:
Parameter
pH value
electrical conductivity
Hydrocarbons
Chloride
Calcium
Total hardness
Iron
Manganese
Copper
Sulphate
Active chloride
free of bad odours
For connection values refer to technical
specifications.
 Insert the inlet hose from the bottom
through the plant opening and connect
it.

Electrical connection

Danger
Risk of electrical voltage. All electrical in-
stallations may only be done by an electri-
cian according to the local regulations.
 Remove the 4 knurled scrwes from the
roof. The screws can be loosened fast-
er when you press the roof from the top.
 Push the roof towards the door until it
protrudes out of the casing on the oppo-
site side.
 Connect the wire to the electrical switch
cabinet.
Adjusting the dosing of the softener liq-
uid (optional)
Danger
Risk of electrical voltage. Setting may only
be done by an electrician.
 Determining the hardness of tap water:
through the public water supply works,
using hardness testing set, order no.
6.768-004.
 Open the switch box at the operator
panel.
14
-
EN
1 Speed potentiometer
Value
6,5...9,5
max. 2000
μS/cm
< 0,01 mg/l
< 250 mg/l
< 200 mg/l
< 28 °dH
< 0,2 mg/l
 Locate the local water hardness in the
< 0,05 mg/l
diagram.
< 0,02 mg/l
 Extend the vertical line upward until the
< 240 mg/l
curve has been reached.
< 0,1 mg/l
 Draw a horizontal line from the intersec-
tion and read the setting value (A).
 Adjust the speed potentiometer to the
value that you have ascertained (A).
Example: For a water hardness of 15 °dH
on the scale for the SS wash 5/10, set the
speed potentiometer to position 7. This re-
sults in a pause of 40 seconds, i.e. the so-
lenoid valve will open briefly every 40
seconds.
 Close the switch box at the operator
panel.
 Put the roof back on
 Oil level has to be between MIN and
MAX.
 Cut off the top of the oil container.
Ceck the oil level