Cleaning the glass pane
The glass must be cleaned when COLD with a
cloth and a few drops of special cleaning liquid
(GlassKamin). Do not clean when the boiler-
stove is operating.
Cleaning the flue
According to different laws in various countries,
it is necessary to have authorized staff clean the
flue.
This must be done before periods of boiler-stove
use and every time a layer of soot and tar (easi-
ly flammable substances) can be seen on the
inside of the duct. When deposits reach a thick-
ness of 5 - 6 mm, high temperatures and sparks
may set them on fire with easily imaginable con-
sequences both for the flue and your home. It is
therefore advisable to clean the flue at least
once a year or in any case when necessary.

Maintenance

Failure to perform maintenance shall forfeit
the guarantee.
In the case of very frequent use of the thermo
stove, cleaning the smoke channel more than
once a year is recommended.
For the maintenance of the chimney flue, also
consider UNI 10847/2000 single smoke
systems for generators fueled with liquid and
solid fuels:
Maintenance and control.
38
SERVICING
FAQ
The answers shown here summarize the infor-
mation found in these specifications.
1) What do I need to have in order to install
KLIMA or WARM?
A smoke outlet of at least 150 mm in diameter
(the outlet must receive smoke from KLIMA or
WARM only).
An air intake in the room of at least 200 cm
Outlet and inlet connections to the manifold.
An outlet to the drain for the high temperature
valve (in the version with coil).
2) Can I use the boiler-stove without connecting
it to the domestic water system?
No. Use without water damages the boiler-
stove.
3) Can I connect the boiler-stove inlet and outlet
directly to a heat emitting unit (radiator)?
No, like all other water heaters, they must be
connected to a manifold from which the water is
distributed to the heat emitting units.
4) Can the KLIMA and WARM stoves also provi-
de domestic hot water?
Domestic hot water may be produced using our
kits 1 - 3 - N3 - N3 BIS (for open expansion tank
installations) and 6 (for closed expansion tank
installations), or produced and stored by one of
our water heaters (see plumbing diagrams). This
use reduces the power available to the radia-
tors.
5) Does there have to be an air intake in the
room?
Yes, to replenish the air in the room there must
be an air intake of at least 200 cm
CHECK LIST
Read the entire specifications
before using this list
Installation and setup
• Installation carried out by an authorized TAC
which has issued the guarantee and mainte-
nance booklet.
.
• Room ventilation.
2
• The smoke duct/flue only receives smoke
from the boiler-stove.
• The smoke duct does not have:
• 90° bends;
• horizontal sections.
• The outlet pipes are made of a suitable
material (stainless steel is recommended).
• Where pipes cross any flammable materials
(e.g. wood), every precaution has been taken
to avoid fire.
• The plumbing has been declared as com-
pliant with Italian law No. 46/90 by an autho-
rized technician.
• The heatable room dimensions have been
suitably calculated considering the heating effi-
ciency of the heat emitting units (radiators).
Use
• The firewood used is good quality and not
damp.
• The heat exchange pipes and parts inside
the firebox are clean.
• The pressure (read on the gauge) is about 1-
1.5 bars.
in diameter.
2
REMEMBER NEVER TO
VACUUM-CLEAN HOT ASH